  1.  
  2.                            Welcome to PC-ECAP
  3.                               Version 2.10
  4.  
  5.     Revision History
  6.  
  7.     Version 2.10 - 11/09/92
  8.     Now handles circuits with up to 90 nodes.  Added option to
  9.     print only circuit description and graphs.  Negative
  10.     inductor values are now accepted.  Changed listing format
  11.     for frequencies of 10 GHz and above.  Added network (LAN)
  12.     support.  Fixed "border flash" when switching from graphics
  13.     to text mode on some CGA cards.  Added table of contents to
  14.     manual.
  15.  
  16.     Version 2.01 - 2/03/92
  17.     Improved syntax checking on the circuit description files.
  18.     More input errors are spotted and flagged.
  19.  
  20.     Version 2.00 - 10/14/91
  21.     Added group delay, impedance, VSWR and return loss
  22.     calculations.  Now has full support for 24 pin printers.
  23.     Now supports HP LaserJet.  Editor has been enhanced.
  24.     Analysis routine is now twice as fast as previous versions.
  25.     Added AT&T and MCGA support.  Added support for a math
  26.     coprocessor.  European format for element values now
  27.     accepted.  Improved error checking on circuit description
  28.     files.  International time and date on printouts now
  29.     supported.  Numbers are now stored in IEEE binary format.
  30.     No longer supports "non-compatible" video.  Now requires
  31.     384K of system memory.
  32.  
  33.     Version 1.11 - 11/23/90
  34.     Added the filename to the headers and plot sheet of the
  35.     printout.  Negative resistance values are now accepted.
  36.     Fixed bug in hard copy plotting routine - plot would display
  37.     spurious points if the plot exceeded the maximum range.
  38.     Fixed bug in analysis routine; Occasionally, a circuit with
  39.     a very wide range of reactive component values could create
  40.     an internal numeric overflow.
  41.  
  42.     Version 1.10 - 9/14/90
  43.     Added the option of 35 sample points to the select number of
  44.     sample points menu.  Greatly increased the number of plot
  45.     ranges available when displaying results.  Magnitude now
  46.     spans .1 db/div to 80 db/div and Phase now spans 22.5
  47.     degrees/div to 720 degrees/div.
  48.  
  49.     Version 1.02 - 1/30/90